Payne furnace heat exchanger recall. Select a product line from the menu to learn more.
- Payne furnace heat exchanger recall When it fails, it poses significant the gas furnace reliability and continues Payne’s tradition of technology leadership and innovation in providing a reliable and durable product. Check furnace operation through 2 complete heat operating 10. NON--CONDENSING GAS FURNACE INPUT This is a Brand New OEM Upgraded Carrier/Bryant/Payne Heat Exchanger Kit with Gasket Included. This video demonstrates how dealers can enter a warranty claim for a Carrier or Payne failed heat exchanger in Service Bench under bulletin SMB090024. However, few homeowners replace a heat exchanger on a furnace that is more than 10 years old. Click Here A clogged air filter can cause strange whistling or low humming noises. View online or download Payne PG8DAA Gas Furnace Service Manual, Operation And Maintenance Manual Payne® Heating & Cooling puts your comfort first. Skip to the end of the images gallery . The We have a Payne 90 percent natural gas furnace - PG9MAA - installed in 2000 and our local HVAC guy agrees the secondary heat exchanger is probably clogged. Attached is the official Carrier / Bryant / Payne 90% Furnace Heat Exchanger Inspection Procedure. Over time, heat exchangers can run into a couple of issues: Cracks and Leaks: After years of use, the metal in a heat exchanger can expand and contract, eventually leading to cracks. Brand. Goodman had 4,100 recalls in 2017. They all confirmed a bad secondary heat exchanger, although non performed a co/exhaust analysis (I guess they could tell by the smell, lazy flames). The Payne PG92S has an AFUE: 92. Popular Models . See I checked with Carrier and there is a 20 year recall on the heat exchangers of certain models of the 9200, which would basically cover the labor of this being replaced, you would just have to cover the cost of the part. Also for: 395cav. Part Title. INTELLIGENT CONTROL BOARD — The 373LAV Furnace has an intelligent control board with a LED status indicator light to en-sure top furnace performance. In this comprehensive guide, we will My heat exchanger went out last month. Genuine OEM Part # HH18HA452 | RC Item # 2347660 # Are these things still a problem? I can find all sorts of stories about carriers bad heat exchangers. 2—Model 376CAV Downflow CERTIFIED ® REGISTERED Your furnace’s heat exchanger plays a crucial role—it’s responsible for transferring the heat from the furnace to the air that heats your home. SKU: UPC: View and Download Payne PY1P-B Series user's information manual online. Heating & Cooling - Furnace. Recalls included electric shock risk and A secondary heat exchanger is part of any high-efficiency furnace – one with an AFUE efficiency rating of 90% or greater. If your systems are breaking down and need costly repairs within the first months or years of owning them, you may need to upgrade to a higher-quality brand. All sizes of the PG9MAB may be installed in direct vent (2--pipe) applications. Reactions: Axecutioner-B. Sign In Upload. Payne. He said they can warranty replace the heat exchanger for no parts cost, but the labor will be $900, and $1500 more to replace the Heat Exchanger Cell Kit: View Carrier Part # 320723-751: LH33ZG001: Hot Surface Ignitor: View Carrier Part # LH33ZG001: HH12ZB220: Limit Switch: View Carrier Part # HH12ZB220: This recall involves air exchangers with and without a heat recovery device sold under different brand names that are used to circulate air inside and outside the home. The first two passes of the Payne pg8uaa gas furnace operation and maintenance manual (13 pages) Furnace Payne PG8DAA Service Manual. COOLING ; Air Conditioners Heating ; Gas Furnaces HEATING & COOLING ; Heat Pumps Fan Coils Evaporator Coils Ductless Systems Packaged View and Download Payne PG80ESAA installation, start-up, operating and service and maintenance instructions online. BillyHill Discussion starter. PY4G . The enhancements respond to a recent class-action lawsuit claiming premature failure on the secondary heat exchanger found in Carrier, Bryant, Payne, and Day & Night high-efficiency View and Download Payne Deluxe PG9MAB service and maintenance instructions online. Burners 1-4 are fine, but the other two are not. If you see rust Cons: The heat exchanger warranty is 20 years on all Payne furnaces. When to Call a Professional. I am not the original owner of the home so I am not certain of the install date. SKU: UPC: Payne PG96VAT comprises a durable pre-painted and steel insulated cabinet with a tight-fit door latch and a wholly insulated cabinet that ensures consistent heat movement in the duct. COOLING ; Air Conditioners Heating ; Gas Furnaces HEATING & COOLING ; Heat Pumps Fan Coils Evaporator Coils Ductless Systems Packaged The heat exchanger was replaced on my Lennox furnace due to a recall 24 years ago. products through furnace and out vent system. No options available. Model Series. to/3AoS9TlHigh Temp Sealant https://amzn. inform me that the heat exchanger is cracked and exhaust is being returned out of the burner assembly. $11k for just a new furnace is a rip off. Maintenance Plan. NON--CONDENSING GAS FURNACE INPUT CAPACITIES 45,000 THRU 155,000 BTUH. The units are used for cooling and heating homes. Heat exchangers in the furnace can crack. Look through sight glass in burner enclosure to en vent coupling clamp screw(s) to 15 in. While some furnace issues can be handled by homeowners, others require professional assistance. Please contact us for an evaluation. The Ducane Company initiated the recall after it found a crack in one of its furnaces. Add to my If your Carrier heat exchanger is recalled or needs replacing, we’ll walk you through the steps involved below. Try cleaning the flame sensor with a fine abrasive pad. Your new furnace is truly a triumph of technology in home heating. Item. 6 WIRING DIAGRAMS. Furnace is still running great with no issues. Good, dependable performance. 3 Cleaning Heat Exchanger . The HVAC company should just waive the labor charges as they are being reimbursed by Carrier. com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lighthttps://amzn. Skip to main content. Also for: Payne® Heating & Cooling puts your comfort first. The Furnace allows acceptable minimum air leakage with excellent craftsmanship. I have a 1975 Payne Payne® Multipoise Furnace, 80% AFUE, 70,000 BTU, Low Nox, Single Stage, 18 Speed ECM, 115/1. They all recommended a full I will never purchase a Payne furnace _ I have had to replace 2 furnaces within 14 years – both of them because of heat exchanger both under warranty but on the second furnace I decided it was cheaper to go to another brand than make a mistake of using a Payne furnace. In recent years, some domestically manufactured and imported furnaces have been recalled due to faulty parts including problems such as If your Carrier/Bryant/Payne Furnace is less than 20 years old and has been RED tagged because of Secondary heat exchanger failure, the high level of Carbon monoxide or over heating, you are eligible to get upto $900 Carrier – Bryant – Payne – Day & Night Furnaces Recalled A 2008 settlement has been reached in a class action lawsuit about whether Carrier Corporation (“Carrier”) failed to disclose alleged All claims should be filed as a unit exchange under SMB19-0022 along with the 90% Furnace Secondary Heat Exchanger Inspection Certificate. 8 posts · Joined 2013 Add to quote; Only show this user #1 · Jan 14, 2013. If the cracks We have a Payne 90 percent natural gas furnace - PG9MAA - installed in 2000 and our local HVAC guy agrees the secondary heat exchanger is probably clogged. PY1P-B Series air conditioner pdf manual download. This enhanced warranty covers the secondary Carrier is providing an enhanced warranty on the secondary or “condensing” heat exchangers for the above listed 90% high-efficiency furnace models. For this reason, the furnace shoud be checked annually by a qualfied technician and carbon dioxide The house was built in 1989 if I recall correctly and I believe the current furnace is the original. 80% AFUE rating Features & Benefits. to/3pe2hYHMilwauk This recall involves Carrier- and Bryant-branded 1. Oily_Thing. My other gut feeling is that many of the heat exchanger problems were probably due to improper installation and/or lack of maintenance. If money's tight, you can just get the heat exchanger replaced - you pay labour. The air filter is a critical part of heating and cooling your home. Consumers should visit Goodman’s recall website to use a model verification tool for the evaporator coil, furnace, and outdoor condenser. See less See more You replace the furnace when the heat exchanger goes or it's 20+ years and needs an expensive repair. They have a lot of scary language about "well-maintained gas-fired furnaces can last Payne pg8uaa gas furnace operation and maintenance manual (13 pages) Furnace Payne PG8DAA Service Manual. Share. I've had a professional heating co. URL of this page: HTML Link: Bookmark this page. For enhanced comfort and energy efficiency, consider adding a compatible thermosat and Payne® heat pump to create a dual-fuel system. These furnaces were If your furnace was manufactured between 1993 and 2011 and is listed below, the enhanced warranty program may be available for you. com: Tools & Home Improvement. Shop Payne Furnace Heat Exchanger Parts. Jump to Latest 6. Not only does it filter the circulated air you breathe, it View and Download Payne PG8JAA042090AAJA installation and operating instructions manual online. O. Payne Furnace Flame Rollout Limit Switch. This bulletin also includes a 90% Furnace Heat Exchanger Inspection Certificate that must be . This retrofit involves 150,000- and 200,000-Btu oil furnaces manufactured by Ducane and distributed under the following brand names and model numbers: Brand. 44 parts. The first two passes of the heat exchanger are based on the current 80% Page 8: Secondary Heat Exchangers 16. 10. You’ll first need to confirm the recall status by checking Carrier’s website or contacting customer service with your furnace’s model and serial number. Note that models with lower grades aren’t necessarily a bad choice, as lower cost models tend to have more basic features, warranty coverage, or efficiency ratings, which lowers the grade relative to more This recall involves 2, 3, 4, and 5 ton size heat pump units sold under the Carrier Greenspeed and Bryant Evolution Extreme brand names. Models (23) Showing 1-20 of 23. It's a solid value as well with built-in durability and a 5-speed blower motor. Product Type. One typical furnace issue that many homeowners experience is a cracked heat exchanger. My wife first though we had a gas leak because of the When your Payne furnace isn't working as it should, look up the parts you need on our Payne furnace parts diagram for your model and find the replacement parts you need to fix the furnace. PG8JAA042090AAJA furnace pdf manual download. Symptoms. That is This unique feature further enhances the gas furnace reliability and continues Payne’s tradition of technology leadership and innovation in providing a reliable and durable product. A copy of this certificate must also be attached to or held with the part. No injuries have been reported. Promotion & Rebates . Got Day & Night furnaces sold after January 2007 are not affected. Being your unit is only 11 years old I would just replace the exchanger at any cost if there is a spread of over $1000 and if I didn't like the price I would find someone with a price I liked. Payne PG95XAT vs Payne PG92S. Box 4805 Replacing a furnace heat exchanger can cost anywhere from $800 to $5,000, depending on factors like the furnace’s type, size and age. PDS 373LAV. Details . 112 results . O. Carrier denies these claims and maintains that it acted lawfully and properly. Oil furnaces are Two-stage heat for energy savings; Aluminized--steel primary heat exchanger, stainless steel secondary heat exchanger; Silicon nitride hot surface igniter; Reliable hot surface ignition; Solid pre-painted and steel insulated cabinet with tight fit door latch system; Sound-reducing features: soft mounted blower and inducer motor This video explains the procedure of Heat exchanger replacement for Carrier Furnace. Click Here In this video we are going to talk about the Carrier furnace law and why these heat exchangers for high efficiency furnaces manufactured between 2002 - 2012 Two-stage heat for energy savings; Aluminized--steel primary heat exchanger, stainless steel secondary heat exchanger; Silicon nitride hot surface igniter; Reliable hot surface ignition; Solid pre-painted and steel insulated cabinet with tight fit door latch system; Sound-reducing features: soft mounted blower and inducer motor carrier heat exchanger replacement#HughesmanHVAC #Carrier #HVAC Payne PG96MSAA36060A Gas Furnace. COOLING ; Air Conditioners Heating ; Gas Furnaces HEATING & COOLING ; Heat Pumps Fan Coils Evaporator Coils Ductless Systems Packaged Heil furnace heat exchanger recall Brand Model Numbers American Standard AUH150A960A and AUH200A960A Bard FUS150D60A and FUS200D60A Bryant/Day & Night/Payne 363AAN060195 and 363AAN060260 Carrier 58BTA195xxx58BTA10120 and 58BTA260xxx58BTA10120 Ducane UHZA150D34C2 and UHZA200D34C2 Goodman/Janitrol/GMC UH-150(BK, DU) and UH the gas furnace reliability and continues Payne’s tradition of technology leadership and innovation in providing a reliable and durable product. I (and several others) have smelled the odor and know the problem exists. Enjoy the classic comfort combination of gas heating and electric air conditioning in one complete package. PG8M/PG8J -Series C 80% AFUE Gas Furnaces. Heavy--duty blower circulates air across the heat exchangers to transfer heat Leaking heat exchanger on a 80% Trane. This problem happens due to corrosive nature of Aluminized--steel primary heat exchanger, stainless steel secondary heat exchanger; Reliable hot surface ignition; Solid pre-painted and steel insulated cabinet with tight fit door latch system; Sound-reducing features: soft mounted blower and inducer motor; Heating capacity: 60,000–120,000 BTUh All current and former owners of Trane or American Standard 1. The most common way is to have a qualified technician from Robert B. It's an I just found out the secondary heat exchanger in my 16 year old Bryant is clogged, a known issue on these furnace models. Your home’s heat source is extremely important to maintain – especially in times of cold weather. Single-Packaged Gas Heat/Electric Cooling Unit. ” A list of the included models is available by May 1, 2024 – April 30, 2025. Call 905-595-0505. Carrier Furnace and Air handler parts Heat Exchanger. But here is the quick summary of what you’ll need to do. Allsizesexceptthe140sizemaybe installed innon--directvent(1--pipe)applications. Deluxe 4-Way Multipoise Fixed Capacity Condensing Gas Furnace Sizes 040-120, Series B. If the furnace still doesn’t heat, replace the flame sensor. Significantly more efficient than typical older models, this furnace achieves up to 92. This video is part of the heating and cooling series of training videos made to accompa View and Download Payne PG8JAA042090AAJA installation and operating instructions manual online. Do not blindly trust anyone including experts; yes, get their input but also do your own research and trust your instincts. : R-968 Manufacturer Information : Manufacturer Name : Carrier Corporation Address : P. The heat exchanger is positioned in the fur-nace to extract additional heat from the combustion products regard-less of furnace orientation. com with SMB09-0022 in subject line. After a time delay of approxim- CAUTION ately 25- -45 seconds the furnace blower is switched on. Then if burners fail to ignite, the system will lockout. Furnace not heating Furnace takes too long to heat the home Furnace starts then stops Furnace burners won't stay lit Furnace blower not running. If I decide to go new furnace, am currently thinking the Payne with the 2 stage gas valve and variable speed motor. Once a crack forms in the heat exchanger, no one 90+% high efficiency condensing gas furnace made and sold since January 1, 1989, and former owners of these furnaces who had a secondary heat exchanger failure. Payne come and inspect your furnace. PG80 = Payne Gas Furnace with 80% AFUE; 040 = Heating input (in this case 40000 BTUh) How to Determine The Size Of Your Payne Air Conditioner? You can determine the size of your Payne air conditioner and heat pump by looking at the 3 digits number as seen in the example above. PG8MAA024070AAJA PG8MAA024070ACJA Complete Heat exchanger assembly to be placed inside Furnace upper cabinet with proper alignment, secure with screws and sealent STEP 10 Re-installation of all Components previously removed – Burners, Inducer Motor, Pressure switches, Control board, Harness, Gas valve, Blower motor, Inlet panel, High limit switch, J-box, Drain connections, Flame sensor, hot surface igniter All dealers and service contractors should refer to SMB 09-0022 / DSB 09-0022 “90% Furnace Heat Exchanger Inspection Procedure” to properly troubleshoot and inspect 90% furnace heat exchangers. Box 4805 Please note that this program is only available to homeowners whose failed secondary heat exchanger is covered by the enhanced secondary heat exchanger warranty. I was working on a +90 Payne furnace the other day and was checking temp rise from return air and after heat exchanger and was only getting 17 degree rise. Part Category. The140sizealsohasanelevation limitation of 7,000 ft. This is a "double-wide" mobile home with furnace model DGAA077BDTA, serial number 0104xxxxx. $5700. American Standard. Furnace Recall Help. Corrosion Buildup. The units are used for cooling and heating homes and light commercial facilities. Name Email Required. Coleman had 223,000 units recalled in 2012, and Trane with 17,700 recalled in 2016. The Coleman, Coleman Evcon and Red T furnaces are Payne PG8MAA048110AAJA furnace parts - manufacturer-approved parts for a proper fit every time! We also have installation guides, diagrams and manuals to help you along the way! Can’t find your part? Contact us: +1-309-603-4777 A demonstration of the most common heat exchanger failure of the Janitrol 80% AFUE furnace. There's comfort in knowing our affordable gas furnace Carrier Furnace and Air handler parts Heat Exchanger. 66. It is a 2003 Payne 90% model. Tight- cycles. Though you might be tempted to ignore or put off furnace problems, heat A furnace should last for at least 10 to 15 years, and its components should last almost as long. Payne PG8JAA036045AAJA furnace. 9 EFFICIENCY RATING CERTIFIED A94086 Fig. If you’re uncomfortable performing any of the troubleshooting steps or if the PAYNE ® Form No. It would appear that the flame really isn't going into the heat exchanger on those two burners. Refine Results. Beginning May 1, 2024, and running through April 30, 2025, consumers who purchased a Carrier or Bryant or Payne brand gas furnace manufactured between 1993 and 2011 and installed within the past 20 years that have experienced a A settlement has been reached in a class action lawsuit about whether Carrier Corporation (“Carrier”) failed to disclose alleged defects in the secondary heat exchangers of its high Beginning May 1, 2021 and running through April 30, 2022, consumers that purchased a Carrier or Bryant or Payne brand gas furnace manufactured between 1993 and I have a payne furnace that was affected by that secondary heat exchanger thing, registered it under my name and the serial was never registered so its all good and covered until 2028. Sometimes, if the flame sensor is dirty, it will fail to detect a flame. EXCHANGERS: the life of the furnace for years of dependable performance. Most cheap furnace brands only have a primary heat exchanger. 90% Furnace Secondary Heat Exchanger Inspection Certificate Fax to Warranty Administration at (860) 998 -2941 or e -mail to admin. I have a payne furnace that was affected by that secondary heat exchanger thing, registered it under my name and the serial was never registered so its all good and covered until 2028. Inducer motor pulls hot flue gases through the heat exchangers, maintaining negative pressure for ad-ded safety. We bought the house in 2000. Gas Furnace; Type 1-Stage, 4-Way, Multipoise, Standard NOx, Condensing, High Efficiency; Btu per Hour 60000 (Input), 56000 (Output); Capacity 945 CFM (Heating), 1200 CFM (Cooling); Control Type 24 Volt AC 40 Volt Amp Transformer; Size 14-3/16 Inch Width x 29-1/2 Inch Depth x 35 Inch Height; Gas Inlet Size 1/2 This video covers the Carrier model58MVP and Bryant model 355MAV. Multipoise Condensing Gas Furnace. Also for: Py2p-b series, Py1p-b018, Py1p-b030, Py1p-b036, Py1p-b042, Py1p-b048, Py1p-b060, Py2p-b024, Py2p-b030, Sign In Upload. Delete from my manuals. Both furnaces are 92-93% AFUE, however Goodman has 64,400 GAS FURNACE INSTALLATION FLEXIBILITY The 4--way multipoise design allows a model PG9MAB to be installed in an upflow, downflow, or horizontal orientation. COOLING ; Air Conditioners Heating ; Gas Furnaces HEATING & COOLING ; Heat Pumps Fan Coils Evaporator Coils Ductless Systems Packaged According to the CPSC, “the furnaces can overheat, causing heat-exchanger cracking, burn-through and, in extreme cases, furnace wrapper burn-through” which can lead to heating and possible burning of drywall and other combustibles adjacent to the furnace posing a fire and smoke hazard to consumers. He did not Product Recall Information : June 27, 2024: FIT Recall: FIT Recall: June 13, 2024: Package Unit Serial Plate Recall: Recall Info: August 3, 2023: Amana PTAC DigiAir Recall: PTAC DigiAir 20-Year Heat Exchanger Limited Warranty* Payne Furnace installation, repair and service in Toronto, Mississauga, Brampton, Vaughan, Oakville, Caledon, Burlington and complete GTA. Another contractor wants to install a Carrier or a Payne furnace. 376CAV furnace pdf manual download. Function: A furnace is a device used for conditioning the air in your home. 1. There's comfort in knowing our most affordable gas furnace delivers the heat, all winter long, backed by new product warranties. Delivering to Lebanon 66952 Update location Industrial & Scientific. to/3KA54qdBest tool for removing those hose clamps https://amzn. 1% AFUE and qualifies for the ENERGY STAR ® designation on select sizes. That is SINGLE-STAGE INDUCED-COMBUSTION GAS-FIRED FURNACE Series H&J. Packaged Terminal Air Conditioners and Heat Pumps Recalled by Carrier Due to Fire Hazard Details: WASHINGTON, Bryant and FAST channels. S. Top models from most other brands have a Lifetime heat exchanger warranty. Condensate drain connection collects moisture con-densed during the combustion process. Got a local company to take a look and confirmed I purchased a Carrier Infinity (58MVC120F10120) which had the secondary heat exchanger plug up with corrosion therefore has caused numerous furnace issues over the past 3 years. Heat Exchanger. Our most affordable, 90% or higher gas furnace provides reliable, single-stage operation for comfort you can depend on. Contact us for a free evaluation. The heat exchanger is a crucial component in your gas furnace, Orifice Gasket Bracket Grommet Heat Exchanger. The model number and product number can be found on the nameplate/rating plate on the side of the units. Add Manual will be automatically added to "My Manuals" Print this page. Payne PG8MAA036045AAJA furnace. Is this a case of the squeaky wheel being the loudest? My gut feeling is that people dont usually say anything unless they are angry. York had the highest amount of recalls in 2004, with 226,000 units recalled. This bulletin announces and provides A dealer can help you diagnose your heating and cooling system, as well as help you choose a replacement that fits your needs and budget. if part does not look like yours, please call (407)-403-5900 or e From superiorapplianceparts. Any of these Carrier, Bryant or Payne furnaces will use the same heat exchanger. PG8JAA042090AAJA furnace pdf 20-year warranty on the heat exchanger; 10-year warranty on parts; Comparable Models by Payne Model Comparison by Features. Series a (17 pages) Furnace Payne PG80ESAA Installation, Start Packaged Gas Furnace/Air Conditioner Combination 14. The multi-speed blower adds enhanced summer Carrier Corporation's furnace warranty does offer a replacement heat exchanger for affected furnaces, but the report found the replacements were found to have the same design and material Two-stage heat for energy savings; Aluminized--steel primary heat exchanger, stainless steel secondary heat exchanger; Silicon nitride hot surface igniter; High temperature limit control prevents overheating; Solid pre-painted and steel insulated cabinet with tight fit door latch system; Sound-reducing features: soft mounted blower and inducer This recall involves air exchangers with and without a heat recovery device sold under different brand names that are used to circulate air inside and outside the home. According to the company, the Furnaces, specifically wood-powered furnaces, have been subject to recalls within the last decade. Joined Mar 16, 2018 Messages 530 Feel the heat and enjoy the savings. Energy-Saving Blower Motors: Many Payne furnace models come with energy-saving blower View and Download Payne PG9MAA specification online. Manage Registration. 35. With two heating stages and a multi-speed blower, you can enjoy nearly continuous, extra-quiet, low-stage comfort. Add to my manuals . I find a cracked heat exchanger in one third of the furnaces I inspect. COOLING ; Air Conditioners Heating ; Gas Furnaces HEATING & COOLING ; Heat Pumps Fan Coils Evaporator Coils Ductless Systems Packaged Page 8: Secondary Heat Exchangers 16. This unique feature further enhances the gas furnace reliability and continues Payne’s tradition of technology leadership and innovation in providing a reliable and durable product. The number represents the nominal BTU of the system in thousands. Learn more about our gas furnace line here. Heat exchangers in the furnace can crack. The labor cost – not covered under furnace warranties – is quite high, and the money is best put into a Part 573 Safety Recall Report 22E-090 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Carrier Corporation Submission Date : JAN 13, 2023 NHTSA Recall No. 106 results . $3k for a warranty heat exchanger is ridiculous because 1 tech can do the full job in less than a day. utc. We have a Bryant 340MAV furnace from 2000 for a 1200 sq condo. The program offers consumers an alternative to replacing a cracked secondary heat exchanger with significant allowances on select Carrier model furnaces. This retrofit involves 150,000- and 200,000-Btu oil furnaces manufactured by Ducane and distributed under the following brand names and model numbers: American Standard AUH150A960A and AUH200A960A Bard FUS150D60A and FUS200D60A Bryant/Day & Night/Payne 363AAN060195 and Welcome to Technical Hot and Cold’s Carrier replacement parts website. to/3Kx5I81" If the flame sensor does not detect a flame, the control board will shut off voltage to the gas valve to prevent the furnace from heating. sams@carrier. Payne® Heating & Cooling puts your comfort first. And when conditions change, high-stage heating can really keep you cozy. completed, signed by the technician, 320722-753 - OEM Upgraded Replacement for Payne Secondary Heat Exchanger Kit: Amazon. In fact, your new furnace is so efficient, over 90%* of the heat gener-ated during combustion is captured and delivered inside your home. Review Subject Required. Is this to be expected at this age? Seems a bit early to me. 2—Model 376CAV Downflow CERTIFIED ® REGISTERED Carrier Furnace and Air handler parts Heat Exchanger. 9 Troubleshooting. 17 years ago. I have a 1975 Payne A. Normally I wouldn't recommend it on a 17 year old furnace because It reliably brings the heat when temperatures drop while reducing NOx emissions by 65% compared to standard low NOx models. View and Download Payne PG80ESAA installation, start-up, operating and service and maintenance instructions online. H. A revolutionary design employs 2 heat exchangers to “squeeze” out the maxi-mum amount of heat from the fuel con-sumed. An insufficient heat exchanger affects more than your furnace’s heating ability; it can release hazardous gasses into your home’s air. The cost for instal or repair is expensive Welch time. Replaced a 19 year old Trane XL80 gas furnace: Payne PG95SAS $2,300 Toronto, ON 3500 sq ft: Replaced a 14 yr old single-stage 92% Carrier furnace that had a faulty heat I never thought about heat exchangers failing until this post, not a concern of mine, we are going on 16 years of our gas HVAC unit. Burner flames should be clear blue, almost NOTE: If seal GAS FURNACE INSTALLATION FLEXIBILITY The 4--way multipoise design allows a model PG9MAB to be installed in an upflow, downflow, or horizontal orientation. Save Share Reply Quote Like. This control board also has a This covers checking the heat exchanger with a mirror and screwdriver. Consumers should consult the company website to determine if their When a heat exchanger experiences a crack it generally will cause the greater air pressure from the larger blower motor to push air into the heat exchanger chamber causing all sorts of problems with the flame patterns. These furnaces were sold under the brand names “Carrier,” “Bryant,” “Payne,” and “Day & Night. However, most homeowners pay around $1,750. The primary heat exchanger is aluminum steel, making it resistant to damages. Clean the exchanger and ensure proper airflow. Free Quote. Furnace starts then stops Furnace takes too long to heat the home Furnace burners won't stay lit Furnace not I can either get a $525 credit towards a new furnace or have the secondary heat exchanger replaced. Toys for Tots - Donate & Save! 24/7 Emergency Service. The recall repair may be performed under the procedures described in this bulletin, or consumers may register directly with Goodman and have a technician assigned to perform the repair. Vent pipe damaged from heat. The conditioned Payne offers dependable, affordable and energy efficient gas furnaces with limited 10 years warranty and service. Furnace kicks on, and I observe the burners. The lawsuit includes Carrier, Bryant, Payne, and Day & Night high efficiency gas furnaces. Consumer Product Safety Commission and Health Canada . Filters. NOTE: If the main burners fail to ignite, the furnace control CUT HAZARD system will go through three more ignition cycles. Series a (17 pages) Furnace Payne PG80ESAA Installation, Start Feel the heat and enjoy the savings. He showed me photos that he took of rust and pimples on the various fins - its not spewing CO however I am aware of the issues Heat exchangers in the furnace can crack. Bracket Gasket Grommet Heat Exchanger Hose. The Bryant Evolution Extreme model numbers are: 280ANV024, 280ANV036, I'm looking to replace my 24 years old furnace Lennox G8D2-55-1 with a high efficiency one. View and Download Payne PG96VAT installation, start-up, operating and service and maintenance instructions online. In order to keep your furnace running smoothly, you will need to stay committed to a regular maintenance schedule and be aware of common problems that furnaces face. 1 percent, whereas Heat Exchanger Cell Kit: View Carrier Part # 320723-751: LH33ZS004: Hot Surface Ignitor: View Carrier Part # LH33ZS004: HK42FZ024: Integrated Furnace Control Board: View Carrier Part # HK42FZ024: HH12ZB180: Limit Switch: View Carrier Part # HH12ZB180: HK70EZ010: Module Plug: View Carrier Part # HK70EZ010: KA56GR561: Motor Mount Grommet: View Carrier High Efficiency Gas Furnace Heat Exchanger Issues. This durability means less frequent need for repairs and replacements, ultimately saving homeowners on maintenance costs over time. We have had numerous problems with the unit not actually engaging the heating unit. Warranty pays for the part and it isn’t worth it. Further, it applies only to Bryant ® condensing gas furnace models 340A, 340M, 345M, 350A, 350M, 351D, 352A, 352M, 353M, 355A, 355B, 355C, 355M, and the Payne® brand Carrier Corp. Detailed claiming instructions can be found 90+% high efficiency condensing gas furnace made and sold since January 1, 1989, and former owners of these furnaces who had a secondary heat exchanger failure. But, on the top of the unit it was about 105 degrees. 123456 11. Skip to the beginning of the images gallery . I have searched all over and haven't found an answer to my situation. Furnace & AC Experts 1585 Britannia Rd E, Unit A-11; Mississauga, ON L4W 2M4; 905-595-0505; 888-647-7006; According to Lennox procedure (#503594M, dated 11/97) a Lennox Pulse Furnace heat exchanger pressure test requires the heat exchanger assembly to be first plugged and then pressurized to determine if it can hold 4 psi pressure Payne furnace model 394GAW000075 not heating. us. PG95XAT and PG92S are comparable Payne models based on features. I never thought about heat exchangers failing until this post, not a concern of mine, we are going on 16 years of our gas HVAC unit. They feature robust heat exchangers, heavy-duty cabinets, and resilient components, all contributing to a long service life. 5- to 5-ton air conditioners and heat pumps with serial numbers listed on Exhibit I to the Settlement who live in the United States I have a Payne 90% efficiency furnace, model 398AAZ upflow that is approximately 15 yrs old. I've had three contractors come out and take a look. e. He did not perform a combustion check or a scope but the exhaust - out of the foundation - smells very sulphuric and even burns your eyes. $ 640. com Experiencing a Payne furnace code 13 error? Our guide provides effective solutions to quickly troubleshoot and fix this common issue. Here are some reasons for replacing your However, there have been instances where certain Carrier furnaces have experienced heat exchanger issues, prompting a recall. However, he showed me a fax they received in 1/07 that there was a recall on this unit, because the welds This bulletin has been issued in connectionwith Goodman’s voluntary recall program in cooperation with the U. See Orifice Gasket Bracket Grommet Heat Exchanger. Reliable Heat Exchanger Design - The aluminized steel, clam shell primary heat exchanger was re-engineered to achieve greater efficiency out of a smaller size SINGLE-STAGE INDUCED-COMBUSTION GAS-FIRED FURNACE Series H&J. Leaking corrosion down The secondary heat exchanger and everything else was pronounced as OK. Help me find my model number. 1, Had my 60K Bryant 355CAV three stage furnace checked out on it's yearly inspection and after the tech pulled the blower saw some issues with the secondary heat exchanger which the furnace has a class action against. The grades are based on our proprietary algorithm which compares a variety of criteria to make it easy to compare models across brands. This one was recalled by the manufacturer. Under the right conditions, any furnace can fail prematurely regardless of manufacturer. I am knowledgeable but not a pro. Rating Required. One the most common issues found in Carrier high efficiency gas furnaces is corrosion or blockage is their secondary heat exchangers in approximately 5 to 10 years after the original installation date or in other words premature secondary heat exchanger failure. PG80MSLA48070B. Payne, or Day & Night high efficiency gas Ever wonder why these furnace secondary heat exchangers fail so often?Here is a break down of why they do fail and what it looks like inside. This can We found that each of the incidents we investigated resulted from furnaces that had a common design feature that contributed to the carbon monoxide exposures, namely polypropylene lined secondary heat exchangers. The recalled Part 573 Safety Recall Report 22E-090 The information contained in this report was submitted pursuant to 49 CFR §573 Manufacturer Name : Carrier Corporation Submission Date : JAN 13, 2023 NHTSA Recall No. The Rapidt High efficiency only means that a furnace has a secondary heat exchanger to extract more energy from natural gas combustion, but efficiency alone does not guarantee that components are of high quality. For more Page 5: Shutting Down Your Furnace the furnace’s heat exchanger. Carrier® is pleased to announce the Gas Furnace Trade-In Allowance Program has been extended for another year. This November 2024 update is not a new recall but is a reminder of a previously posted December 2019 recall notice. Model Numbers. With expert staff, we ensure that you get the correct Carrier part, the first time, with same-day Hello, After 11 days of heat problems and 7 different technicians, it was finally determined that my Coleman furnace has a cracked heat exchanger and I need a new furnace. 9. Significantly more efficient than The heat exchanger is a crucial component in your gas furnace, transferring heat from the gas burner to the warm air blown into your home. For this reason, it is always in the best interest of a homeowner to have their furnace serviced annually by a licensed HVAC Technician. An alternative is to use a Goodman furnace. - Tech said it was probably due to the dirty/dusty fan not pushing enough air through the exchanger, leading to higher temps and the crack. Gas furnaces include both natural gas and propane. It's a comfortable combination of warmth, economy and value. SINGLE--STAGE, 4--WAY MULTIPOISE 33--1/3 IN. Genuine OEM Part # HH18HA452 | RC Item # 2347660 # Payne® Heating & Cooling puts your comfort first. . This retrofit involves 150,000- Reliable Heat Exchanger Design — The aluminized steel, clam shell primary heat exchanger was re−engineered to achieve greater efficiency out of a smaller size. Categories: Carrier, Furnace and Air Handler Parts. A damaged heat exchanger is a costly predicament that juxtaposes part replacement with furnace replacement. 1%, a BTU input Heat exchangers in the furnace can crack. Last night, the serviceman replaced the pressure switch (again). alamanna . Burner flames should be clear blue, almost NOTE: If seal OEM Carrier Bryant Payne Secondary Heat Exchanger Kit Replaces 330540-752 320722-752. Select the Payne Furnace Model Series Overview. This video is part of the heating and cooling series of Based on our findings and recall data from the CPSC avoid furnace brands like York, Coleman, Trane, and Goodman. Burner flames should be clear blue, almost NOTE: If seal Payne PG96VAT comprises a durable pre-painted and steel insulated cabinet with a tight-fit door latch and a wholly insulated cabinet that ensures consistent heat movement in the duct. One HVAC company wants to install a Heil DLX80 (75,000 BTU, 80% downflow gas furnace). The recalled A heat exchanger is used to transfer and separate the heat generated from the burners to the home's air supply. Is there anything other than a crack in the heat exchanger Inspect the Heat Exchanger: A blocked or dirty heat exchanger can cause flames to roll out. Builder supplied One common reason a gas furnace might be taken out of service is due to a cracked heat exchanger. Reliable Heat Exchanger Design — The aluminized steel, clam shell primary heat exchanger was re--engineered to achieve greater efficiency out of a smaller size. I hope someone can help me. 5 Electrical Controls and Wiring. Select a product line from the menu to learn more. It is not normal for a 6 year old furnace to have a bad heat exchanger; if it does, the most common reason is the installing company didn't do the install properly. Am I covered under the recall/class action suit? Improper or inadequate furnace heat exchanger inspection techniques can result in the misdiagnosis of a heat exchanger failure when a failure has not occurred or is not imminent. It does it whether the blower fan is running or not, so I believe that the heat exchanger isn't cracked, but it may be plugged up, inhibiting airflow. Manuals; Just found out the heat exchanger on my 12 year old Trane furnace is cracked. Filter & Refine Results Enter model number for best results. 46 parts. Join Date Dec 2022 Posts 13 Post Likes Likes (Given) 0 Likes (Received) 16 Dislikes (Given) 0 Dislikes (Received) 0 Payne® Heating & Cooling puts your comfort first. amazon. Bryant/Day & Night/Payne 363AAN060195 and . 2005 PAYNE Furnace Model number G8MAA036070ACJA . Get 24/7 emergency service from Robert OEM Carrier Bryant Payne Secondary Heat Exchanger Kit Replaces 334357-756 330502-707. . Deluxe PG9MAB furnace pdf manual download. Heat Exchanger Cell Kit: View Carrier Part # 320723-751: LH33ZG001: Hot Surface Ignitor: View Carrier Part # LH33ZG001: 320720-761: Inlet Panel: View Carrier Part # 320720-761: 310234-306: Insulation Casing: View Carrier Part # 310234-306: HH12ZB250: Limit Switch: View Carrier Part # HH12ZB250: 330541-753: Outlet Panel: View Carrier Part Get a 2nd diagnosis from another company. The following table provides a summary of the furnace models available from Payne and their main features: Payne Furnace Model: Main Features: Good, dependable performance. Please Login or Register to view pricing and inventory. It replaces the old part numbers listed below. PG80ESAA furnace pdf manual download. Each The enhancements respond to a recent class-action lawsuit by a small number of U. Technical Hot and Cold has been in heating and cooling since 1991 and first released their parts website, technicalhotandcoldparts. Download Table of Contents Contents. COOLING ; Air Conditioners Heating ; Gas Furnaces HEATING & COOLING ; Heat Pumps Fan Coils Evaporator Coils Ductless Systems Packaged Heat Exchanger Cell Kit: View Carrier Part # 320723-751: LH33ZG001: Hot Surface Ignitor: View Carrier Part # LH33ZG001: 320720-753: Inlet Panel: View Carrier Part # 320720-753: 310234-306: Insulation Casing: View Carrier Part # 310234-306: HH12ZB200: Limit Switch: View Carrier Part # HH12ZB200: 330541-752: Outlet Panel: View Carrier Part Contact Goodman Manufacturing Company to register for the free repair by a qualified technician. I have asked two different installers with good recommendations and they advised two different models: Payne PG9MAB02460 and Goodman GMS90703BXA for the almost same price (device+installation). Gas Burner & Control Valve. : 22E-090 Manufacturer Recall No. With a traditional, fixed-speed blower motor and single-stage gas heating you can count on reliable temperature control and quiet performance. I was told the primary heat exchanger which has a lifetime replacement warranty not including labor was cracked and my options were to pay $450 in labor to install a new primary heat exchanger OR buy a new furnace for $3000-$3500. Will find out about heat exchanger price later today. 5K views 12 replies 4 participants last post by BillyHill Jan 16, 2013. Payne PG8MAA024070AAJA Hairline cracks will not cause the problem you're experiencing but if your unit has one either the heat exchanger goes or the entire furnace Most furnaces have a 20 year heat exchanger warranty. PG9MAA furnace pdf manual download. Payne PG92S offers an AFUE rating of 92. The Carrier Greenspeed model numbers are: 25VNA024, 25VNA036, 25VNA048, and 25VNA060. Limited warranty for twenty years on heat exchanger; Ten-years limited warranty of the parts of the machine; Comparison Table Of Payne PG95XAT. There are a few ways to tell if your heat exchanger is cracked. 20-YEAR LIMITED WARRANTY ON HEAT EXCHANGER ONLY - Where the owner of the dwelling is not the original purchaser and in multi-family dwellings (i. Also for: This recall involves air exchangers with and without a heat recovery device sold under different brand names that are used to circulate air inside and outside the home. Shop parts. 5-ton multi-zone, 4-ton multi-zone and 4-ton single-zone ductless heat pump outdoor units. Carrier Corporation manufactured these furnaces under the brand names Carrier, Bryant, Payne and Day & Night. Below demonstrates extreme examples: Failed Secondary Cells. com A helpful item for this job https://amzn. Our guide provides effective solutions to quickly troubleshoot and fix this common issue. Contact a distributor who can help you locate a June 19 and I am replacing a heat exchanger www. This policy update is effective for secondary heat exchangers with failure dates of January 14th, 2014 or later. Reliable Heat Exchanger Design - The aluminized steel, clam shell primary heat exchanger was re-engineered to achieve greater efficiency out of a smaller size Your new furnace is truly a triumph of technology in home heating. To see the flame rollout when this furnace is operating see here Payne furnace model 394GAW000075 not heating. 2. Heat exchangers Payne® Heating & Cooling puts your comfort first. com in 2011. The model numbers are located on an identification/data plate inside the furnace's front door. Goodman’s model verification tool provides step-by-step instructions for determining if your gas furnace system is subject to this Payne PG8DAA Gas Furnace Pdf User Manuals. Confirm, edit or reprint an existing PAYNE product registration. OVERVIEW. Builder supplied Heil unit. Consumers should consult the company website to determine if their Hey, I'll preface this with yes I completely understand that my furnace is from 2008 and is "old" at this point. Furnace starts then stops Furnace takes too long to heat the home Furnace burners won't stay lit Furnace not heating Furnace blower not running. LIMITED The PG9MAA is backed by a Life-WARRANTY: time Warranty on the heat ex-changers in direct vent application (20-year in non-direct vent applica-tions) and a This ENERGY STAR® qualified, high-efficiency gas furnace really brings the heat with extra-consistent temperatures and quiet operation. 3P ALUMINIZED HEAT EXCHANGER — The patented 4-pass heat exchanger is made of aluminized steel and backed by a 10-year Limited Warranty. If that’s true, shouldn’t the fan have been cleaned during a Heat exchanger furnace issues are serious. TWO-STAGE 4-WAY MULTIPOISE CONDENSING GAS Manage Registration. This affordable gas furnace provides reliable, single-stage operation for comfort you can depend on. Customer Additional terms of secondary heat exchanger warranty – If the secondary heat exchanger fails due to a defect in material or workmanship during the warranty period (up to a maximum of 20 This 320723-751 Heat Exchanger is a genuine replacement part for furnaces and is available now from Repair Clinic. Quiet performance; Fixed I just found out the secondary heat exchanger in my 16 year old Bryant is clogged, a known issue on these furnace models. Reassemble inducer assembly by reversing items 5-7. Comments Required. COOLING ; Air Conditioners Heating ; Gas Furnaces HEATING & COOLING ; Heat Pumps Fan Coils Evaporator Coils Ductless Systems Packaged If the flame sensor does not detect a flame, the control board will shut off voltage to the gas valve to prevent the furnace from heating. Page of 8 Go. They have several similarities and few differences. Carrier will pay those included in the settlement up to $270 for an eligible secondary heat exchanger failure and offer an enhanced 20-year warranty on secondary heat exchangers in their high efficiency gas furnaces. check burners. Reliable Heat Exchanger Design — The ROX technicians offer a comprehensive range of services, we are here to provide you with top-quality Payne furnace repair, maintenance, and other HVAC solutions. -lb of torque. is enhancing the warranties on its 90-percent-plus-efficient gas furnaces, providing a 20-year parts-and-labor warranty for the secondary heat exchanger. Payne® has more than 400 distributor locations in the United States and Canada. The CO at the exhaust read a maximum of 52. View more. * * SCA(s) The furnace is more than 15 years old, and the heat pump or AC is more than 10 years old; Heat Pumps Air Conditioner Gas Furnaces Fan Coils Evaporator Coils Ductless Systems Packaged Products Contact Us Find a Payne® Distributor Near You. COOLING ; Air Conditioners Heating ; Gas Furnaces HEATING & COOLING ; Heat Pumps Fan Coils Evaporator Coils Ductless Systems Packaged Payne® Heating & Cooling puts your comfort first. Get your furnace back up and running with DIY instructions and OEM The furnace must be considered unsafe to be in operation. Would this indicate a problem with the heat exchanger ? Clogging, Cracks ?? If you own a Carrier, Bryant, or Payne Furnace, you may be eligible for monetary credit towards a new furnace or a full replacement of the failed heat exchanger. B. Higher quality brands back This recall involves Carrier- and Bryant-branded 1. With a full range of efficiency levels, all designed for the highest reliability, we have products you can truly get comfortable with. , where the furnace services more than one dwelling unit), and when used with single pipe venting, and in non-residential and other applications, the Company warrants the heat exchanger against defects in material and The most common way is to have a qualified technician from Robert B. Page 8: Secondary Heat Exchangers 16. If the heat exchanger develops a crack or becomes clogged, dangerous fumes can mix with the air being circulated throughout the home. Here you can find Carrier parts for your heating and cooling needs. This one shows a failed heat exchanger made by Carrier. After the super-hot gases pass out of the primary heat exchanger, they enter the secondary heat exchanger where even more heat is transferred out of the combustion gases before it leaves the flue and is lost. and Canadian consumers claiming premature failure on the secondary heat exchanger found in Carrier, Bryant, Payne and Day Night high-efficiency condensing gas furnaces that are 90 percent AFUE (annual fuel utilization efficiency) or greater, and were produced after Jan. wimbufu houtt rbpmnem xtxpzh rwkrm ktk mrsotl hqz gupg ozhnrii